Datos del Documento


Por favor, use este identificador para citar o enlazar este documento: https://ria.asturias.es/RIA/handle/123456789/12427
Registro de Metadatos Completo
Campo Dublin Core Valor Idioma
dc.contributor.authorCosta-Rama, Estefanía-
dc.contributor.authorNouws, Henri P.A.-
dc.contributor.authorDelerue-Matos, Cristina-
dc.contributor.authorBlanco-López, M. Carmen-
dc.contributor.authorFernández-Abedul, M.Teresa-
dc.date.accessioned2019-11-21T08:44:23Z-
dc.date.available2019-11-21T08:44:23Z-
dc.date.issued2019-05-09-
dc.identifier.citationE.Costa-Rama et. al. Preconcentration and sensitive determination of the anti-inflammatory drug diclofenac on a paper-based electroanalytical platform. Anal Chim Acta 2019; 1074: 89-97eng
dc.identifier.other10.1016/j.aca.2019.05.016-
dc.identifier.urihttp://ria.asturias.es/RIA/handle/123456789/12427-
dc.description.abstractThis work describes the development of a paper-based platform for highly sensitive detection of diclofenac. The quantification of this anti-inflammatory drug is of importance in clinical (e.g. quality- and therapeutic control) and environmental (e.g. emerging contaminant determination) areas. The easy-to-handle platform here described consists of a carbon-ink paper-based working electrode and two metallic wires, provided by a gold-plated standard connector, as reference and counter electrodes. The porous paper matrix enables the preconcentration of the sample, decoupling sample and detection solutions. Thus, relatively large sample volumes can be used, which significantly improves the sensitivity of the method. A wide dynamic range of four orders of magnitude, between 0.10 and 100 µM, was obtained for diclofenac determination. Due to the predominance of adsorption at the lowest concentrations, there were two linear concentration ranges: one comprised between 0.10 and 5.0 µM (with a slope of 0.85 µA µM-1) and the other between 5.0 and 100 µM (with a slope of 0.48 µA µM-1). A limit of detection of 70 nM was achieved with this simple device. The platform provided accurate results with an RSD of ca. 5%. It was applied for diclofenac quantification in spiked tap water samples. The versatility of this design enabled the fabrication of a multiplexed platform containing eight electrochemical cells that work independently. The low cost, small size and simplicity of the device allow on-site analysis, which is very useful for environmental monitoring.eng
dc.description.sponsorshipThe authors would like to thank the EU and FCT / UEFISCDI / FORMAS for funding, in the frame of the collaborative international consortium REWATER financed under the ERA-NET Cofund WaterWorks 2015 Call. This ERA-NET is an integral part of the 2016 Joint Activities developed by the Water Challenges for a Changing World Joint Programme Initiative (Water JPI). This work was also supported by the EU (FEDER funds throught COMPETE) and FCT (project FOODnanoHEALTH, Portugal2020, Norte-01-0145-FEDER-000011 and project UID/QUI/50006/2013) and by the Spanish Ministry of Economy and Competitiveness (MINECO, project CTQ2014-58826-R). Estefanía Costa Rama thanks the Government of Principado de Asturias and Marie Curie-Cofund Actions for the post-doctoral grant “Clarín-Cofund” ACA17-20eng
dc.language.isoengeng
dc.publisherElseviereng
dc.relation.ispartofAnalytica Chimica Actaeng
dc.relation.haspart1074eng
dc.relation.isreferencedbyNo, esta versión no ha sido citadaeng
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/deed.eseng
dc.source89;97-
dc.subject.classificationPublicadoeng
dc.titlePreconcentration and sensitive determination of the anti-inflammatory drug diclofenac on a paper-based electroanalytical platformeng
dc.typearticleeng
Aparece en las colecciones: Open Access DRIVERset
Química

Archivos en este documento:
Fichero Tamaño Formato  
Archivo1.pdf1.3 MBAdobe PDFVer/Abrir
Mostrar el registro Básico


Ver estadísticas del documento


Este documento está sujeto a una licencia Creative Commons: Licencia Creative Commons Creative Commons