Título: Adjustment recommendations of a conoscopic holography sensor for a reliable scanning of surfaces with roughness grades obtained by different processes
Autores: Rico, José Carlos
Valiño, Gonzalo
Fernández, Pedro
Zapico, Pablo
Blanco, David
Mateos, Sabino
Palabras Claves: Conoscopic Holography
Non-contact scanning
Fecha Edición: Oct-2015
Cita Bibliográfica: Rico, J. C., Valino, G., Fernández, P., Zapico, P., Blanco, D., & Mateos, S. (2015). Adjustment recommendations of a conoscopic holography sensor for a reliable scanning of surfaces with roughness grades obtained by different processes. Precision Engineering, 42, 335-345.
Datos de Serie/Reporte No.: DOI
10.1016/j.precisioneng.2015.04.011
Resumen: Conoscopic holography (CH) is a non-contact interferometric technique used in surface digitizing. Like other laser techniques it is influenced by different factors such as surface reflectance, material, colour or even speckle noise caused by roughness. In this work, a CH system was used for analysing the influence of roughness on surface digitizing. For this purpose, several digitizing tests were performed on roughness specimens corresponding to EDM, face milling and flat grinding processes. Each roughness grade was digitized under different combinations of the sensor setting parameters (frequency F and power P) which satisfy that the signal acquired by the sensor lies within the quality values recommended by the manufacturer. The results were analysed by using two indicators that show quality of the points captured by the sensor regarding the surface geometrical reconstruction and its metrological reliability. Finally, the study provides a series of recommendations for adjusting the sensor in order to satisfy both indicators simultaneously.
Descripción : Estudio de la calidad de los resultados de digitalizado utilizando un sensor de Holografía Conoscópica sobre materiales obtenidos por diferentes procesos y con diferentes calidades superficiales. Recomendación de parámetros de ajuste del sensor.
URI: https://ria.asturias.es/RIA/handle/123456789/6542
ISSN: 0141-6359
Aparece en las Colecciones:Ingeniería
Open Access DRIVERset

Archivos en este documento:



Archivo TamañoFormato
Archivo.pdf132,25 kBAdobe PDFVer/Abrir



logo

Todos los documentos en RIA están protegidos por derechos de autor.


Valid XHTML 1.0! DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Contacto