Autor : Rico, José Carlos
Valiño, Gonzalo
Fernández, Pedro
Zapico, Pablo
Blanco, David
Mateos, Sabino
Palabras clave : Conoscopic Holography
Non-contact scanning
Fecha de publicación : oct-2015
Citación : Rico, J. C., Valino, G., Fernández, P., Zapico, P., Blanco, D., & Mateos, S. (2015). Adjustment recommendations of a conoscopic holography sensor for a reliable scanning of surfaces with roughness grades obtained by different processes. Precision Engineering, 42, 335-345.
Citación : DOI
10.1016/j.precisioneng.2015.04.011
Resumen : Conoscopic holography (CH) is a non-contact interferometric technique used in surface digitizing. Like other laser techniques it is influenced by different factors such as surface reflectance, material, colour or even speckle noise caused by roughness. In this work, a CH system was used for analysing the influence of roughness on surface digitizing. For this purpose, several digitizing tests were performed on roughness specimens corresponding to EDM, face milling and flat grinding processes. Each roughness grade was digitized under different combinations of the sensor setting parameters (frequency F and power P) which satisfy that the signal acquired by the sensor lies within the quality values recommended by the manufacturer. The results were analysed by using two indicators that show quality of the points captured by the sensor regarding the surface geometrical reconstruction and its metrological reliability. Finally, the study provides a series of recommendations for adjusting the sensor in order to satisfy both indicators simultaneously.
Descripción : Estudio de la calidad de los resultados de digitalizado utilizando un sensor de Holografía Conoscópica sobre materiales obtenidos por diferentes procesos y con diferentes calidades superficiales. Recomendación de parámetros de ajuste del sensor.
URI : https://ria.asturias.es/RIA/handle/123456789/6542
ISSN : 0141-6359
Aparece en las colecciones: Ingeniería
Open Access DRIVERset

Archivos en este documento:
Fichero Tamaño Formato  
Archivo.pdf132.25 kBAdobe PDFVer/Abrir
Mostrar el registro Completo


Ver estadísticas del documento


Este documento está sujeto a una licencia Creative Commons: Licencia Creative Commons Creative Commons